LAB  PRECISION   W A T T - M E T E R   SIEMENS & HALSKE / Germany (1900)
************************************************************************
Width = 23 cm / 9" ;  Depth = 32 cm / 12_1/2" ;  Height = 12 cm / 4_3/4"
SCALE  =  0 .. 150                                          SN = 2803243
       =  1 kΩ ;    25 A ( 7 mΩ ; 20 μH )    /    50 A ( 1.7 mΩ ; 5 μH )
Results from  T E S T S  ( see below):
======================================
MAXIMAL:   ( DC / AC )  1500 W   =   ( 300 V * 5 A ) ... ( 30 V * 50 A )
CALIBRATION FACTORS:     » 25 A «   =  x5    /    x10  =   » 50 A «
VOLTAGE-INPUT on the BLACK CLAMPS ;  the  CURRENT-INPUT on BRASS CLAMPS.
The SWITCH on front  changes the POLARITY  for the instrument ;  and the
SCREW above is for  ZERO-ADJUST  of the instrument.  The BRIDGES have to
be set either to  » 25 A « (shown)  or to  » 50 A «.
      Have a Look at a home-made TEST-UNIT ...
Some  T H E O R Y ...
   | 
| ... adapted from O.MOHR "Elektrotechnik" (1961) Picture from "Kleine Enzyklopaedie" TECHNIK (1956) A Look I N S I D E ... |   | 
| 
 |