Albert Nestler, Lahr in Baden / Germany (1940)
**************************************************************
VERSION (B)
S C A L E S of the NESTLER » E L E K T R O « Model 37
==============================================================
Front Side Back Side
==============================================================
( 0 .. 25 cm Ruler )
V X * 1.75
(A) PS X2
--------------------------------------------------------------
(B) KW X2 S sin(0.1X)
( 30 .. 54 cm RULER IN BASE ) S&T arc(0.01X)
(C) X T tan(0.1X)
--------------------------------------------------------------
(D) X
U X * 5.24
--------------------------------------------------------------
(LL2) exp(0.1X) = keyed to SCALE A and LEFT CURSOR-MARK
(K) X3
R E M A R K S : ( 1° = 60' ; 1' = 60" )
==============================================================
The TRIGONOMETRIC SCALES are divided in MINUTES & SECONDS
The no-named scales are marked here with their common symbols
in brackets: (A),(B),(C),(D),(LL2),(K).
The U-Scale is folded by ( for calculating "Revol./Minute" )
π / 60 = 0.05236
The V-Scale is folded by the "Specific Resistance of Copper"
sRcu = 0.0175 Ω * mm2 / m
The CU-Marks for "Specific Conductivity of Copper"
sCcu = 57.2 m / Ω * mm2 = 1 / sRcu
The 736-Mark for
1 PS = 0.7355 kW with "Effectiveness"-Marks for
MOT (=Motor) & DYN (= Dynamo)
The Mark sqrt(2g) = 4.429 for "Pressure Hight" calculations
There are 3 Versions of "Model 37" in this collection:
In this VERSION (B) the CURSOR IS FRAMELESS AND
-----------------------------------------------
the cursor's hairlines are different and NOT SYMMETRICAL:
The CENTRAL (black) and the RIGHT (red) are in the common
distance (on A-Scale) AREA/DIAMETER (on X-Scale) - but the
LEFT (red) is SHIFTED to the left (= 736-Mark Distance).
Because the cursor's side-window was missing, it had to be
h o m e - m a d e with this C A L I B R A T I O N :
-----------------------------------------------------------
Set the cursor's central hairline at "2" on X-Scale, the
right hairline on the SIDE-WINDOW (green) has to read "8"
on K-Scale. Set cursor's left hairline at "10" on A-Scale
(the central hairline now at DYN on A-Scale), the left
hairline on the SIDE-WINDOW (red) has to read "e" on LL2.
There is ANOTHER VERSION ( X ) on earth !!!
-------------------------------------------
The NESTLER BOOKLET "Electro No.37" (i.German), is showing
a "Model 37" with a DIFFERENT CURSOR & DIFFERENT SCALES ...
In VERSION (A):
The CURSOR HAIRLINES are symmetrical and in the common
distance (on A-Scale) AREA/DIAMETER (on X-Scale).
The LL2-Scale is UNDER the CUBIC-Scale and SHIFTED so,
that CUBIC "45" is over LL2 "e" = ONLY 1 SIDE-HAIRLINE.
In VERSION (C):
The SR is longer, has a red 1/X and "extended" Scales.
The CURSOR HAIRLINES are symmetrical again and in the
common distance (on A-Scale) AREA/DIAMETER (on X-Scale).
The LL2-Scale is placed OVER the CUBIC-Scale and SHIFTED,
that CUBIC "52" is under LL2 "e". 2 CURSOR SIDE-Hairlines.
Historical Remarks ...
The slide rule came in a black cardboard case. It is made of
mahogany with scales on celluloid veneer. The back side's
table with constants was missing - and also the cursor's
side-window was missing and had to be home-made (s.above).
impressum:
***************************************************************
© C.HAMANN http://public.BHT-Berlin.de/hamann 10/11/21
|